Cloudy, Dull Water

December 4, 2011

Possible Cause
pH too high.

Solution
Test pH and total alkalinity. Add pH DOWN as directed. Adjust as required.

Preventative Maintenance
Test frequently and maintain pH of 7.2-7.8 and total alkalinity at 80-120 ppm.

—-

Possible Cause
Free chlorine residual too low

Solution
Test for chlorine residual and adjust as needed. Shock treat with OXY-BRITE.

Preventative Maintenance
Maintain free chlorine level of 1-3 ppm.

—-

Possible Cause
Filter not removing small particles

Solution
Use SUPER BLUE to coagulate small particles. Check filter operation.

Preventative Maintenance
Use SUPER BLUE weekly, 1 oz. per 5000 gallons.

—-

Possible Cause
Backwashing sand filters too often

Solution
Backwash less frequently, only as recommended by filter manufacturer’s directions.

Preventative Maintenance
Use FILTER RINSE each time you backwash.

—-

Possible Cause
Dissolved metals in water

Solution
Use SEQUA-SOL to control metals in water.

Preventative Maintenance
Use 4 oz. per 10,000 gallons of SEQUA-SOL weekly to prevent staining and scale formation.